u/omegote

Tried rewinding an old spool of PLA and woke up the next day to this...
▲ 2.8k r/3Dprinting

Tried rewinding an old spool of PLA and woke up the next day to this...

I had a spool of 7-year-old PLA from a defunct Spanish company called BQ. I had to rewind it because the spool did not fit the AMS. Went to bed and woke up to this mess. The PLA has apparently exploded. It was so stiff due to the years so this was kind of expected anyway, I'm not even mad, just impressed. Good thing it happened within the container.

u/omegote — 14 hours ago

My Elitedesk 800 G3 Mini's NVME is running TOO HOT

I've been having random, weird errors with my HP Elitedesk 800 G3 Mini, where I run proxmox with some services (nothing fancy). It has a 1TB NVME and a 1TB SSD, and apparently the temperatures in the NVMe are just too hot and may be the reason behind the random problems.

# nvme smart-log /dev/nvme0n1
Smart Log for NVME device:nvme0n1 namespace-id:ffffffff
critical_warning                        : 0
temperature                             : 39 °C (312 K)
available_spare                         : 100%
available_spare_threshold               : 10%
percentage_used                         : 1%
endurance group critical warning summary: 0
Data Units Read                         : 4938424 (2.53 TB)
Data Units Written                      : 9134801 (4.68 TB)
host_read_commands                      : 30902083
host_write_commands                     : 467405707
controller_busy_time                    : 625
power_cycles                            : 62
power_on_hours                          : 2806
unsafe_shutdowns                        : 49
media_errors                            : 0
num_err_log_entries                     : 0
Warning Temperature Time                : 35
Critical Composite Temperature Time     : 5
Temperature Sensor 1                    : 46 °C (319 K)
Temperature Sensor 2                    : 80 °C (353 K)
Temperature Sensor 3                    : 39 °C (312 K)
Thermal Management T1 Trans Count       : 4
Thermal Management T2 Trans Count       : 0
Thermal Management T1 Total Time        : 828
Thermal Management T2 Total Time        : 0

The temperature sensor 2 is permanently running so hot, I don't really know what to do. I'm open to some DIY in order to improve the temps and the airflow, but I have found nothing on the internet. Any ideas?

reddit.com
u/omegote — 6 days ago