u/Deformedpye

Ok, I really need help with this now as I can't understand what is happening. Long story short. I am getting constant return loss on cables. Some pass, some don't. The HDTDR looks fine. No NEXT. Insertion looks fine. Impedance is fine. I have got the guys to do the basics of changing the RJ plugs and modules. Still the same. The only thing i can see being the issue is because we are going over the 100m (We are utilising PoE extenders to allow for longer runs). The profile we are using is DE Eval Cat 6A 305m (LA). This is actually a stress test, not a cert test. There is no way on a Fluke to create your own to allow longer lengths. We can't do a standard as it will fail on length. Please, can someone help me with this. I have everyone at work and London Underground asking me why and i just can't answer.