I'm getting PS 5421 ILLEGAL COMMAND IN G43.4/G43.5 in O0999 which had an operation before the concerned block. However I posted the selected operation separately in O0998 and I worked just fine. I'm unable to figure out what the problem is as the codes are similar.
O0999
.....
X-1.6742 Y-1.3325 Z-2.5841
X-1.6757 Y-1.3358 Z-2.5359
G00 Z2.
G05.1 Q0
G49
M09
M05
M528 T1
G91 G28 Z0.
G28 X0. Y0.
M39
M11
G28 A0. C0.
M01
N2
(OPERATION NO - 5)
(OPERATION TYPE - ROUGHING 5AX)
T2 M06(0.1875 BULL ENDMILL)
M07
G54 G17 G90
G00 A-80.323 C114.598
G68.2 X0. Y0. Z0. I114.598 J279.677 K0.
G53.1
X.0006 Y.8295
G69
G94
G05.1 Q1
G43.4 H2
X-1.514 Y-.6925 Z-.5576 S4074 M03 T7
X-.8921 Y-.4078 Z-.6742
S2139
G01 X-.7969 Y-.3642 Z-.6921 F15.
S4074
......
O0998
N1
(OPERATION NO - 5)
(OPERATION TYPE - ROUGHING 5AX)
T2 M06(0.1875 BULL ENDMILL)
M07
G54 G17 G90
G00 A-80.323 C114.598
G68.2 X0. Y0. Z0. I114.598 J279.677 K0.
G53.1
X.0006 Y.8295
G69
G94
G05.1 Q1
G43.4 H2
X-1.514 Y-.6925 Z-.5576 S4074 M03
X-.8921 Y-.4078 Z-.6742
S2139
G01 X-.7969 Y-.3642 Z-.6921 F15.
S4074
......