▲ 2 r/Fanuc
Fanuc NOT READY state
I’m trying to recover a FANUC 0T control on a Schaublin 125 lathe that lost its parameters after a battery failure.
The initial issue was:
- Error 911 (RAM parity high)
- Then 910 (RAM parity low)
The battery was completely dead and the control appears to have lost all data. I have installed new batteries.
Now there are no alarms, but the control is stuck in a NOT READY state:
- Cannot change screens
- Cannot load backup via RS232
- No response from the control
Power supply seems OK and boards are properly seated.
The axis/drives display just shows two dashes (“--”), like the system never fully initializes.
This does not look like an E-stop condition.
Questions:
- Could this be caused by completely missing parameters and/or PMC data?
- Is it possible that the system software is also missing or not initializing?
- Is there any way to force the control into a parameter/system load mode without access to the menus?
I do have a backup of the parameters, but I can’t get the machine into a state where it accepts them.
Any help would be greatly appreciated
u/MarcosViudes — 11 days ago