How do I clear old Cable Diagnostic data for switchports ?
The Arista Cable Diagnostics for BASE-T Ports documentation says to run multiple tests to get correct diagnostic results. Is there a way to clear the old test data, so that it's not factored into test results ?
Switch-720XP96-012#test l1 cable base-t int eth 85
! Testing cables will cause Et85 to flap. Continue? [y/N]y
Switch-720XP96-012#show int eth 85 cable detail
Current system time: Wed May 13 10:47:57 2026
Ethernet85
Cable test runs: 8
Cable length accuracy: +/-10m
Current State Changes Last Change
------------------ --------------- ------- -----------
Diagnostics status completed 16 0:00:08 ago
Cable status faulty 1 0:46:29 ago
Status of pair A interpair short 1 0:46:29 ago
Status of pair B ok 1 0:46:29 ago
Status of pair C interpair short 1 0:46:29 ago
Status of pair D interpair short 1 0:46:29 ago
Length of pair A 2m 1 0:46:29 ago
Length of pair B 41m 6 0:11:18 ago
Length of pair C 1m 5 0:00:08 ago
Length of pair D 2m 6 0:00:08 ago
Thanks!