▲ 2 r/whoop
Chatting with AI about my future with Whoop after six years, the AI stated that
Since Whoop 5, the rate changed from 100 Hz to 25 Hz to save battery. Which makes the rate while working out lower than the Apple Watch's rate and therefore leads to that lower performance compared with AW.
Yes, that AW is better with HR tracking. I read more than once, but did they reduce the performance deliberately? Is that AI hallucination or true?
Here the table:
| Device | Sampling Rate | Sensor Type | Wear Location |
|---|---|---|---|
| Polar H10 (chest strap, reference) | 1000 Hz | ECG | Chest |
| Polar Verity Sense | 135 Hz (SDK mode) / ~55 Hz default | Optical (PPG, 6 LEDs) | Upper arm |
| Apple Watch | Several hundred Hz during active measurement (not officially disclosed) | Optical (PPG) | Wrist |
| Whoop 5.0 | 26 Hz | Optical (PPG) | Wrist |
| Whoop 4.0 | Advertised as 100 Hz, actual rate unclear | Optical (PPG) | Wrist |
u/Bastikuhn — 16 days ago